How to cite item

Radioembolization with 90Y glass microspheres for the treatment of unresectable metastatic liver disease from chemotherapy-refractory gastrointestinal cancers: final report of a prospective pilot study

  
@article{JGO8945,
	author = {Nicholas Fidelman and Robert K. Kerlan Jr and Randall A. Hawkins and Miguel Pampaloni and Andrew G. Taylor and Maureen P. Kohi and K. Pallav Kolli and Chloe E. Atreya and Emily K. Bergsland and R. Kate Kelley and Andrew H. Ko and W. Michael Korn and Katherine Van Loon and Ryan M. McWhirter and Jennifer Luan and Curt Johanson and Alan P. Venook},
	title = {Radioembolization with  90 Y glass microspheres for the treatment of unresectable metastatic liver disease from chemotherapy-refractory gastrointestinal cancers: final report of a prospective pilot study},
	journal = {Journal of Gastrointestinal Oncology},
	volume = {7},
	number = {6},
	year = {2016},
	keywords = {},
	abstract = {Background: This prospective pilot single-institution study was undertaken to document the feasibility, safety, and efficacy of radioembolization of liver-dominant metastatic gastrointestinal cancer using 90Y glass microspheres.
Methods: Between June 2010 and October 2013, 42 adult patients (26 men, 16 women; median age 60 years) with metastatic chemotherapy-refractory unresectable colorectal (n=21), neuroendocrine (n=11), intrahepatic bile duct (n=7), pancreas (n=2), and esophageal (n=1) carcinomas underwent 60 lobar or segmental administrations of 90Y glass microspheres. Data regarding clinical and laboratory adverse events (AE) were collected prospectively for up to 5.5 years after radioembolization. Radiographic responses were evaluated using Response Evaluation Criteria in Solid Tumors (RECIST), version 1.1. Time to maximum response, response duration, progression-free survival (PFS) (hepatic and extrahepatic), and overall survival (OS) were measured.
Results: Median target dose and activity were 109.4 Gy and 2.6 GBq per treatment session, respectively. Majority of clinical AE were grade 1 or 2 in severity. Patients with colorectal cancer had hepatic objective response rate (ORR) of 25% and a hepatic disease control rate (DCR) of 80%. Median PFS and OS were 1.0 and 4.4 months, respectively. Patients with neuroendocrine tumors (NET) had hepatic ORR and DCR of 73% and 100%, respectively. Median PFS was 8.9 months for this cohort. DCR and median PFS and OS for patients with cholangiocarcinoma were 86%, 1.1 months, and 6.7 months, respectively.
Conclusions: 90Y glass microspheres device has a favorable safety profile, and achieved prolonged disease control of hepatic tumor burden in a subset of patients, including all patients enrolled in the neuroendocrine cohort.},
	issn = {2219-679X},	url = {https://jgo.amegroups.org/article/view/8945}
}